All new homes built require a building permit. However, according to the NEC, some requirements exist when replacing 2-prong outlets with 3-prong outlets.Ĭode compliance refers to building codes and permits.

#Electrical outlet hidden safe code#

Even today, 2-prong outlets are legal and code compliant inside existing homes.

#Electrical outlet hidden safe update#

Homes built with 2-prong outlets are “grandfathered,” and update is not required to be code compliant. Electrical code compliance for grounded outlets is necessary to build a house or renovations where drywall or plaster are removed. Since 1962, the National Electric Code has required grounded outlets. Electrical shorts with ungrounded circuits can cause severe injury or even death. Electronics like computers and household appliances can also short circuit or cause an electrical shock when plugged into an ungrounded outlet. With the ground absent, hazards like arcing inside the outlet will result in electrical sparks, resulting in a fire. House fires are the most common hazard connected to ungrounded outlets. See the chart below: Size House Cost Small House $1500 – $3000 Medium House $3500 – $8000 Large House $8000 – $20,000 These numbers are averages and will vary based on individual situationsĪ grounded wire is essential because it provides a straight path for that current to travel back to the main breaker panel.

#Electrical outlet hidden safe plus#

In fact, according to, the cost to rewire a house averages about $7 per linear foot of wall space plus $1200 to $2500 for an electrical panel upgrade. However, the only recognized way to ground an ungrounded outlet is by rewiring the circuit- which can be costly. Changing ungrounded outlets to grounded outlets is highly recommended because they prevent electrical hazards. The problem arises when DIYers and amateur electricians remove two-prong outlets and replace them with three-prong outlets without replacing the electrical wiring or following NEC guidelines.

#Electrical outlet hidden safe install#

You can use two NEC-approved methods to safely install 3-prong outlets on ungrounded wiring that we will discuss in a moment. Short cuts to avoid rewiring a circuit is dangerous and unnecessary. However, two-prong outlets (2-prong) did not have this requirement because the grounding path did not exist. In summary, the NEC Section 406.4(D) states that if a grounding path, such as the grounding prong on a three-prong receptacle (3-prong), exists, it should be grounded. The only way to safely ground an ungrounded receptacle is to rewire the circuit with an electrical wire with a bare copper wire for grounding. When overloaded, the electrical current travels through any conductor to ground itself to the earth, damaging electronic devices plugged into the circuit or causing electrocution when in contact with people.Īs homes age, the protective sheathing on the electrical wiring starts to break down, which can cause electrical shorts or arcing to occur, resulting in a fire or electrical shock hazard. Ungrounded wiring was standard in pre-1970s homes. In contrast, modern residential wiring has a hot, neutral, and ground wire.

electrical outlet hidden safe

Ungrounded wiring has a “hot wire” and a “ neutral wire,” but no copper ground wire is present.

electrical outlet hidden safe

Ungrounded wiring can date back to when knob-and-tube wiring was prevalent. Ungrounded outlets are commonly 2-prong outlets, indicating that the home’s wiring is ungrounded. In summary, ungrounded outlets lack the ground wire necessary to provide the same level of safety from house fires and electrical shocks offered by grounded outlets. Read on and know-how! What’s Wrong With Ungrounded Outlets?

electrical outlet hidden safe

Ungrounded outlets have several hazards, but there are ways to keep you and your family safe from house fires, electric shocks, etc.

electrical outlet hidden safe

Let’s dive into what ungrounded outlets are and why they are dangerous. Safe Electricity is a public awareness program of the Energy Education Council. The dangers of ungrounded outlets are echoed in this article, where Molly Hall, Director of Safe Electricity, discussed the dangers of ungrounded outlets and circuits. Other sources and electricians, such as Inspectapedia, KolbElectric, and Parker Young Construction, to name a few, concur that ungrounded outlets are not safe and that grounded outlets are safer. According to Restoration Master Finder, a leader in the home restoration industry, ungrounded outlets top the list of causes of electrical house fires.